Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180346

RESUMO

In this paper, we present the design and commissioning results of the upgraded collective Thomson scattering diagnostic at the Wendelstein 7-X stellarator. The diagnostic has a new radiometer designed to operate between the second and third harmonics of the electron cyclotron emission from the plasma at 171-177 GHz, where the emission background has a minimum and is of order 10-100 eV. It allows us to receive the scattered electromagnetic field with a significantly improved signal-to-noise ratio and extends the set of possible scattering geometries compared to the case of the original instrument operated at 140 GHz. The elements of the diagnostic are a narrowband notch filter and a frequency stabilized probing gyrotron that will allow measuring scattered radiation spectra very close to the probing frequency. Here, we characterize the microwave components applied to the radiometer and demonstrate the performance of the complete system that was achieved during the latest experimental campaign, OP2.1.

2.
J Chem Phys ; 157(10): 104104, 2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36109222

RESUMO

An atomic-orbital reformulation of the Laplace-transformed scaled opposite-spin (SOS) coupled cluster singles and doubles (CC2) model within the resolution of the identity (RI) approximation (SOS-RI-CC2) is presented that extends its applicability to molecules with several hundreds of atoms and triple-zeta basis sets. We exploit sparse linear algebra and an attenuated Coulomb metric to decrease the disk space demands and the computational efforts. In this way, an effective sub-quadratic computational scaling is achieved with our ω-SOS-CDD-RI-CC2 model. Moreover, Cholesky decomposition of the ground-state one-electron density matrix reduces the prefactor, allowing for an early crossover with the molecular orbital formulation. The accuracy and performance of the presented method are investigated for various molecular systems.

3.
Phys Rev Lett ; 127(22): 225001, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34889640

RESUMO

We assess the magnetic field configuration in modern fusion devices by comparing experiments with the same heating power, between a stellarator and a heliotron. The key role of turbulence is evident in the optimized stellarator, while neoclassical processes largely determine the transport in the heliotron device. Gyrokinetic simulations elucidate the underlying mechanisms promoting stronger ion scale turbulence in the stellarator. Similar plasma performances in these experiments suggests that neoclassical and turbulent transport should both be optimized in next step reactor designs.

5.
Nature ; 596(7871): 221-226, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34381232

RESUMO

Research on magnetic confinement of high-temperature plasmas has the ultimate goal of harnessing nuclear fusion for the production of electricity. Although the tokamak1 is the leading toroidal magnetic-confinement concept, it is not without shortcomings and the fusion community has therefore also pursued alternative concepts such as the stellarator. Unlike axisymmetric tokamaks, stellarators possess a three-dimensional (3D) magnetic field geometry. The availability of this additional dimension opens up an extensive configuration space for computational optimization of both the field geometry itself and the current-carrying coils that produce it. Such an optimization was undertaken in designing Wendelstein 7-X (W7-X)2, a large helical-axis advanced stellarator (HELIAS), which began operation in 2015 at Greifswald, Germany. A major drawback of 3D magnetic field geometry, however, is that it introduces a strong temperature dependence into the stellarator's non-turbulent 'neoclassical' energy transport. Indeed, such energy losses will become prohibitive in high-temperature reactor plasmas unless a strong reduction of the geometrical factor associated with this transport can be achieved; such a reduction was therefore a principal goal of the design of W7-X. In spite of the modest heating power currently available, W7-X has already been able to achieve high-temperature plasma conditions during its 2017 and 2018 experimental campaigns, producing record values of the fusion triple product for such stellarator plasmas3,4. The triple product of plasma density, ion temperature and energy confinement time is used in fusion research as a figure of merit, as it must attain a certain threshold value before net-energy-producing operation of a reactor becomes possible1,5. Here we demonstrate that such record values provide evidence for reduced neoclassical energy transport in W7-X, as the plasma profiles that produced these results could not have been obtained in stellarators lacking a comparably high level of neoclassical optimization.

6.
Rev Sci Instrum ; 92(3): 033546, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820048

RESUMO

An ion cyclotron emission (ICE) diagnostic is prepared for installation into the W7-X stellarator, with the aim to be operated in the 2022 experimental campaign. The design is based on the successful ICE diagnostic on the ASDEX Upgrade tokamak. The new diagnostic consists of four B-dot probes, mounted about 72° toroidally away (one module) from the neutral beam injector, with an unobstructed plasma view. Two of the B-dot probes are oriented parallel to the local magnetic field, aimed to detect fast magnetosonic waves. The remaining two probes are oriented poloidally, with the aim to detect slow waves. The radio frequency (RF) signals picked up by the probes are transferred via 50 Ω vacuum-compatible coaxial cables to RF detectors. Narrow band notch filters are used to protect the detectors from possible RF waves launched by the W7-X antenna. The signal will be sampled with a four-channel fast analog-to-digital converter with 14 bit depth and 1 GSample/s sampling rate. The diagnostic's phase-frequency characteristic is properly measured in order to allow measuring the wave vectors of the picked up waves.

7.
Rev Sci Instrum ; 90(9): 093501, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31575247

RESUMO

Fusion reactors and long pulse fusion experiments heavily depend on a continuous fuel cycle, which requires detailed monitoring of exhaust gases. We have used a diagnostic residual gas analyzer (DRGA) built as a prototype for ITER and integrated it on the most advanced stellarator fusion experiment, Wendelstein 7-X (W7-X). The DRGA was equipped with a sampling tube and assessed for gas time of flight sample response, effects of magnetic field on gas detection and practical aspects of use in a state of the art fusion environment. The setup was successfully commissioned and operated and was used to observe the gas composition of W7-X exhaust gases. The measured time of flight gas response was found to be in the order of a second for a 7 m sample tube. High values of magnetic field were found to affect the partial pressure readings of the DRGA and suggest that additional shielding is necessary in future experimental campaigns.

8.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386539

RESUMO

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

9.
Rev Sci Instrum ; 90(2): 023501, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30831775

RESUMO

In this paper, we present a method for numerical computation of collective Thomson scattering (CTS). We developed a forward model, eCTS, in the electrostatic approximation and benchmarked it against a full electromagnetic model. Differences between the electrostatic and the electromagnetic models are discussed. The sensitivity of the results to the ion temperature and the plasma composition is demonstrated. We integrated the model into the Bayesian data analysis framework Minerva and used it for the analysis of noisy synthetic data sets produced by a full electromagnetic model. It is shown that eCTS can be used for the inference of the bulk ion temperature. The model has been used to infer the bulk ion temperature from the first CTS measurements on Wendelstein 7-X.

10.
Rev Sci Instrum ; 90(1): 013503, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709181

RESUMO

A Collective Thomson Scattering (CTS) diagnostic is installed at Wendelstein 7-X for ion temperature measurements in the plasma core. The diagnostic utilizes 140 GHz gyrotrons usually used for electron cyclotron resonance heating (ECRH) as a source of probing radiation. The CTS diagnostic uses a quasi-optical transmission line covering a distance of over 40 m. The transmission line is shared between the ECRH system and the CTS diagnostic. Here we elaborate on the design, installation, and alignment of the CTS diagnostic and present the first measurements at Wendelstein 7-X.

11.
Rev Sci Instrum ; 87(8): 083505, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27587121

RESUMO

Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m(2) per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m(2) per MW injected beam power is measured.

12.
Rev Sci Instrum ; 86(11): 113504, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628132

RESUMO

The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

13.
Rev Sci Instrum ; 83(10): 10D730, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126902

RESUMO

The critical issues in the development of diagnostics, which need to work robust and reliable under quasi-steady state conditions for the discharge durations of 30 min and which cannot be maintained throughout the one week duration of each operation phase of the Wendelstein 7-X stellarator, are being discussed.

14.
Rev Sci Instrum ; 81(10): 10E133, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033995

RESUMO

The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

15.
Rev Sci Instrum ; 81(10): 10E134, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033996

RESUMO

A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique.

16.
Br J Ophthalmol ; 93(8): 1121-5, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19416938

RESUMO

BACKGROUND: A rotary cell-culture system (RCCS) allows the creation of a microgravity environment of low shear force, high-mass transfer and three-dimensional cell culture of various cell types. The aim of the study was to evaluate the growth pattern and the secretory function of rabbit lacrimal gland acinar cells in a microgravity environment using an RCCS. METHODS: Lacrimal gland acinar cells from male New Zealand White rabbits were isolated and cultured in an RCCS up to 28 days. Cells were analysed by light and electron microscopy, and apoptosis was assessed by the TUNEL assay at days 7, 14, 21 and 28. Secretory function was tested by measuring the beta-hexosaminidase activity. RESULTS: After 7 days of culture, spheroidal aggregates were found inside the RCCS. The spheroids consisted of acinus-like cell conglomerates. Apoptotic centres inside the spheroids were observed at all time points by means of the TUNEL assay. Evaluation of the secretory function revealed beta-hexosaminidase release after carbachol stimulation which decreased over the culture period. CONCLUSION: A simulated microgravity environment promotes the development of three-dimensional cell spheroids containing viable acinar cells up to 28 days. Due to the evolving central apoptosis, it is unlikely that such simple three-dimensional cell communities can serve as tissue equivalents for clinical transplantation, but they promise opportunities for further applications in basic and applied cell research on lacrimal gland cells.


Assuntos
Aparelho Lacrimal/citologia , Simulação de Ausência de Peso , Animais , Apoptose , Carbacol/farmacologia , Técnicas de Cultura de Células/métodos , Divisão Celular , Fragmentação do DNA , Marcação In Situ das Extremidades Cortadas/métodos , Aparelho Lacrimal/efeitos dos fármacos , Aparelho Lacrimal/enzimologia , Aparelho Lacrimal/ultraestrutura , Masculino , Microscopia Eletrônica , Coelhos , Esferoides Celulares/ultraestrutura , beta-N-Acetil-Hexosaminidases/metabolismo
17.
Rev Sci Instrum ; 79(10): 10F337, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044644

RESUMO

The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m(2) from radiation alone and of up to about 500 kW/m(2) on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m(2) need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

18.
Transbound Emerg Dis ; 55(8): 339-51, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18786073

RESUMO

A benefit-cost analysis of vaccination for foot-and-mouth disease (FMD) was conducted in an area of South Sudan, which due to chronic conflict, had been subject to large-scale humanitarian assistance for many years. The study used participatory epidemiology (PE) methods to estimate the prevalence and mortality of acute and chronic FMD in different age groups of cattle, and the reduction in milk off-take in cows affected by FMD. The benefit-cost of FMD vaccination was 11.5. Losses due to the chronic form of FMD accounted for 28.2% of total FMD losses, indicating that future benefit-cost analyses for FMD control in pastoral and agropastoral areas of Africa need to consider losses caused by chronic disease. Participatory epidemiological methods were also used to assess the importance of milk in the diet of Nuer agropastoralists, and seasonal variations in diet in relation to cattle movements and FMD outbreaks. Marked seasonal variation in diet included a 'hunger gap' period during which households were highly dependent on milk as their main source of food. Outbreaks of FMD occurred immediately before this period of milk dependency, with chronic losses extending through this period and affecting human food security. The paper discusses the need and feasibility of mass vaccination and strategic vaccination for FMD in South Sudan. The paper also discusses the value of combining conventional benefit-cost analysis with livelihoods analysis to inform disease control efforts and funding commitments in humanitarian contexts.


Assuntos
Doenças dos Bovinos/prevenção & controle , Vírus da Febre Aftosa/imunologia , Febre Aftosa/economia , Febre Aftosa/prevenção & controle , Vacinas Virais/administração & dosagem , Animais , Bovinos , Doenças dos Bovinos/epidemiologia , Controle de Doenças Transmissíveis , Análise Custo-Benefício , Surtos de Doenças/prevenção & controle , Surtos de Doenças/veterinária , Feminino , Lactação , Masculino , Leite/metabolismo , Sudão/epidemiologia , Vacinação/veterinária
19.
Ophthalmologe ; 105(1): 7-18, 2008 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-18210120

RESUMO

For many decades, conventional buckling surgery has been the gold standard for treating rhegmatogenous retinal detachment. The surgical technique has not changed markedly during this period; the three main buckling techniques currently used are the radial sponge, segmental sponge, and encircling band. With one of these options, an anatomic success rate of over 90% can be achieved in "simple" forms of retinal detachment. In pseudophakic eyes, however, the primary reattachment rate after buckling procedures is lower. Pneumatic retinopexy, because of its lower success rate, has not found general acceptance in Europe and is used only in selected cases. Concerning the results of the SPR study, many vitreoretinal surgeons were surprised that in the subgroup of phakic eyes, scleral buckling surgery achieved a comparable reattachment rate and better functional results even in this group of patients with complex hole configuration. This gives physicians reason to critically question the current trend of primary vitrectomy even in eyes with uncomplicated preoperative pathology and to reassess scleral buckling surgery. The longer learning curve to perform buckling surgery should be accepted. Because successful repair depends on careful preoperative examination, thorough training in binocular ophthalmoscopy skills with scleral depression should remain an essential part of the surgeon's education.


Assuntos
Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Descolamento Retiniano/cirurgia , Recurvamento da Esclera/instrumentação , Recurvamento da Esclera/métodos , Vitrectomia/instrumentação , Vitrectomia/métodos , Alemanha , Humanos , Procedimentos de Cirurgia Plástica/tendências , Vitrectomia/tendências
20.
Ophthalmologe ; 105(3): 262-8, 2008 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-17899116

RESUMO

PURPOSE: Autosomal dominant (familial) exudative vitreoretinopathy (adEVR) is a rare, congenital disease of the retinal vascular system, which may lead to blindness in severely affected eyes. One of the causative disease genes is located on chromosome 11q13-q23 and codes for "frizzled-4" (FZD4), a protein involved in vascular differentiation. METHOD: Examination of two families with adEVR over six and four generations and FZD4 mutation analysis. RESULTS: In family I, 18 examined affected members exhibited a heterozygous missense mutation (p.G492R) in the FZD4 gene. In family II, four examined family members were affected and carried a heterozygous deletion of five nucleotides (c.1286del5). Both mutations are novel and showed 100% penetrance and variable expressivity. CONCLUSIONS: With detection of the "family-specific" FZD4 gene mutation, carriers amongst offspring of affected family members can be identified at an early time. The complete penetrance of FZD4 mutations may justify abandoning repeated examinations of offspring of affected family members, if no mutations were detected in FZD4.


Assuntos
Cromossomos Humanos Par 11/genética , Receptores Frizzled/genética , Mutação , Doenças Retinianas/genética , Corpo Vítreo , Adolescente , Adulto , Exsudatos e Transudatos , Feminino , Angiofluoresceinografia , Genes Dominantes , Genótipo , Humanos , Masculino , Linhagem , Fenótipo , Receptores Acoplados a Proteínas G , Doenças Retinianas/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...